9. RESPONSE VIEW

Select [View

→ Response View] from the menu or press the Frequency response indication button on the

HPF/PEQ, Filter or Xover View to show or hide the Response View. The Response View can display the
output response and Xover response.

9.1. Output Response View

• Displays an overall response from input to output.
• Permits selection of Inputs routed by matrix for each output channel.
• Permits display of 3 types of responses: amplitude, phase and group delay responses.

(1)

(2)

(3)

(4)

(5)

(1) Response indication selection button

Displays the types of frequency responses being currently displayed. If this button is pressed, the type of
frequency response to be displayed can be selected from the pull-down menu. There are a full-screen
display that displays any one of amplitude, phase and group delay responses, and a dual-split screen
display that displays two of these 3 responses.

(2) Scale change button

Press this button. A dialog for scale setting is then displayed and
the graph scale of the response control can be changed.

(3) Response indication area

(4) Input selection button [Output 1 – 8]

Press this button to determine whether or not to display the response of each output channel and select
input channels from the pull-down menu.