8.13. Digital Input Module View

(Available only when the D-923AE is used)

Click the "D-923AE" box displayed on the input slot in the Flow View. The Digital Input Module View is then

displayed.

(1)

(2)

(3)

(1) Channel status indication [Status]

Displays the input signal status of the selected channel.

Display

Input signal status

LOCK

Normal

UNLOCK

No cable connected or equipment power not
turned on

Non AUDIO

Not an audio signal

Non PCM

Not PCM data

DTS CD

DTS CD

The indications are shown by black text on white background for the LOCK status, and white text on red
background for the error status.
In error status, the error status indicator lights red on the "D-923AE" box in the Flow View as shown below.

(2) Sampling frequency indication [Fs (Hz)]

Displays the sampling frequency of the selected channel.

(3) Pre-emphasis ON/OFF status [Pre Emphasis]