20.3.2. Auto mixing function

[Gate Settings]

Setting Item

Setting Range

Threshold Level

–50 to +20 dB (–40 dB), 1 dB steps

Hysteresis

0 to +10 dB, 1 dB steps

Depth

∞ to 0 dB (–20 dB), 1 dB steps

Hold Time

10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s

Attack Time

10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s

Release Time

10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s

ON/OFF

ON, OFF

[Ducker Settings]

Setting Item

Setting Range

Priority Level

1 – 8 (in order of the priority level from high to low)

Depth

∞ to 0 dB (–20 dB), 1 dB steps

Attack Time

10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s

Release Time

10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s

ON/OFF

ON, OFF

[NOM Attenuation Settings]

Setting Item

Setting Range

Attenuation Gain

0 log

10

NOM – 20 log

10

NOM (10)

ON/OFF

ON, OFF

[Level Sense Settings]

Setting Item

Setting Range

Attack Time

0.2, 0.5, 0.7, 1.0, 1.5, 2, 3, 5, 7, 10, 20, 50, 70, 100, 120, 150, 200,
250, 300, 500, 700 ms
1, 2, 3, 5 s

Release Time

10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5 s

20.3.3. Settings when the D-921E or D-921F is used

Setting Item

Setting Range

Phantom Power

ON, OFF

PAD (Input Sensitivity)

–50, –36, –10, +4 dB

[Auto-Mixing Group Settings]

Setting Item

Setting Range

Auto-Mixing Group

GROUP A, GROUP B, GROUP C, GROUP D