29

(6) Gate threshold button [Gate Threshold (dB)]

Displays the gate threshold level for each channel by means of
numerical values. If you press this button, a dialog for threshold
level setting is displayed, enabling you to set the level by directly
entering a numerical value. (Setting range: –50 to +20 dB.) You can
also change the threshold level in 1 dB units with the Up and Down
buttons located on the right side.

(7) Gate hysteresis button [Gate Hysteresis (dB)]

Displays the gate hysteresis for each channel by means of
numerical values. If you press this button, a dialog for hysteresis
setting is displayed, enabling you to set the hysteresis by directly
entering a numerical value.
Setting range: –

∞ (–70) to +10 dB

You can also change the hysteresis in 1 dB units with the Up and
Down buttons located on the right side.

(8) Gate depth button [Gate Depth (dB)]

Displays the gate depth for each channel by means of numerical
values. If you press this button, a dialog for depth setting is
displayed, enabling you to set the depth by directly entering a
numerical value.
Setting range: –

∞ (–70) to 0 dB

You can also change the depth in 1 dB units with the Up and Down
buttons located on the right side.

(9) Gate hold button [Gate Hold (ms)]

Displays the gate holding time for each channel by means of numerical values. Pressing this button
permits setting values to be selected from the pull-down menu. The Up and Down buttons located on the
right side can also be used to change the value.

(10) Gate attack button [Gate Attack (ms)]

Displays the gate attack time for each channel by means of numerical values. Pressing this button
permits setting values to be selected from the pull-down menu. The Up and Down buttons located on the
right side can also be used to change the value.

(11) Gate release button [Gate Release (ms)]

Displays the gate release time for each channel by means of numerical values. Pressing this button
permits setting values to be selected from the pull-down menu. The Up and Down buttons located on the
right side can also be used to change the value.

(12) Gate ON/OFF button [Gate On/Off]

Displays the ON/OFF setting status of the gate function for each channel. Press this button to determine
whether (ON) or not (OFF) to use the gate function.

(13) Gate status indicator [Gate Close]

Lights blue when the gate operates (closes).

Advertising