4 cuetype node [optional, 5 cuetypeparameters [optional – Doremi DSV-J2 User Manual

Page 61

Advertising
background image

15.2.7.4 CueType Node [optional]

The CueType element corresponds to the type of Cue used by the TriggerCue. The available
Cue Types are listed in the table below:

Table 3: Cue Types Available

Type

Description

GPI

Allows assignment of a GPI line and value to the Trigger

Signal

Allows assignment of another signal to the Trigger

15.2.7.5 CueTypeParameters [optional]

The CueTypeParameters element contains the parameters associated to the Cue type defined
in the CueType element (Figure 57).

Figure 57: TriggerCue Structure

Dotted lines denote optional elements that can be omitted during the creation based on

the Macro Editor.

 For GPI Cue Type, the two following parameters have to be used:

Line and Value.

The Line element specifies the GPI line number to be used for the associated command. It
contains an integer to be chosen between 0 and 7.

The Value element indicates the state of the GPI: ON (Value = 1) or OFF (Value = 2).

 For Signal Cue Type, the following parameter has to be used: Name.

The Name element specifies the signal name.