2 proper power off – Doremi DSV-J2 User Manual

Page 9

Advertising
background image

 Insert each drive all the way, one by one, in the chassis HDD cage according to the

TOP-CENTER-BOTTOM location defined in the schema below and while making sure
that the grey handle remains open all the way to the right (Figure 3):

Figure 3: DSV-J2 Front View Schema – HDDs Location

The drive shall be inserted all the way inside the HDD cage before trying to close the
grey handle. Otherwise, the drive might not be plugged in properly (Figure 4):

Figure 4: DSV-J2 HDD Cage – HDDs Insertion

 Close the grey handle by pushing it toward the HDD until it clicks. The HDD properly

installed should then look like the CENTER and BOTTOM HDDs presented in Figure 4
above.

 Power cables can now be safely plugged into the DSV-J2.

2.2 Proper Power Off

Follow the instruction below to power off the DSV-J2 safely. Any other method might damage
the raid and result in raid failure:

 Select Shut Down from the Logout menu: Menu → Logout → Shutdown

or

 Press and release the Power button.
1.Note: Do not hold the Power button for more than one second. See section 3.1 for power

switch location.

To turn it back on, simply press and release the Power switch.

DSV.OM.000391.DRM

Page 9 of 68

Version 1.3

Doremi Labs