Flowdde, 2 flowdde – Bronkhorst EL-FLOW Prestige User Manual

Page 18

Advertising
background image

Bronkhorst High-Tech B.V.

EL-FLOW Prestige

9.17.084

18

3.4.2

FlowDDE

RS232 communication can be used for operating the instrument using the Bronkhorst FlowDDE server application. Dynamic Data

Exchange (DDE) provides the user a basic level of interprocess communication between Windows applications. FlowDDE is a DDE

server application. Together with a client application, either self-made or with a SCADA-program from third parties, it is possible to

create an easy way of data exchange between the flow meter/controller and a Windows application. For example, a cell in

Microsoft Excel could be linked to the measured value of the EL-FLOW Prestige and when the measured value changes, it will be

updated automatically in the Excel spreadsheet.

The FlowDDE server offers the user a different and user-friendly interface to the instrument. FlowDDE makes use of specific

parameter numbers for communicating with the instrument. A DDE-parameter number is a unique number in a special FlowDDE

instruments/parameter database and not the same as the parameter number from the process on an instrument. Node-address

and process number will be translated by FlowDDE to a channel number.

DDE-client applications communicate to the FlowDDE server by using DDE messages. Before messages can be exchanged, a DDE link

has to be made. A DDE link consists of three parts: the server, the topic and an item. For separation the characters '|' and '!' may be

used, so a DDE link in e.g. Microsoft Excel becomes: Server|Topic!Item.

For standard instrument parameters and the FlowDDE server, these are:

Server: FlowDDE or FlowDDE2
Topic: ‘C(X)’ for channel number X
Item: ‘P(Y)’ for parameter number Y

An example of a DDE link in a Microsoft Excel cell is =FlowDDE|’C(1)’!’P(8)’ to read parameter 8 of channel 1.

How to setup a DDE link with FlowDDE is described in the

help-file of the FlowDDE application and in the instruction

manual document 9.17.067. Programming examples are

available for making applications in: Visual Basic, LabVIEW

and Microsoft Excel.

When not using FlowDDE for communication with the

instrument, each parameter value is addressed by:

Node address of the instrument
Process number on the instrument
Parameter number on the instrument

Refer to section 3.9 for more information regarding

instrument parameters.

i

www

For more information regarding FlowDDE, see document 9.17.067 'Instruction manual FlowDDE' which can be found

on: http://www.bronkhorst.com/files/downloads/manuals_english/917067manual_flowdde.pdf