3-27

MC6802

• MC6808 • MC6802NS

Bus Timing Characteristics

Ident.

Number

Characteristics Symbol

MC6802NS

MC6802
MC6808

MC68A02
MC68A08

MC68B02
MC68B08

Unit

Min. Max. Min. Max. Min. Max.

1 Cycle

Time

t

cyc 1.0 10 0.667

10 0.5 10

µS

2

Pulse Width, E Low

PW

EL 450 5000 280 5000 210 5000 ns

3

Pulse Width, E High

PW

EH 450 9500 280 9700 220 9700 ns

4

Clock Rise and Fall Time

t

r,

t

f --- 25 --- 25 --- 20 ns

9

Address Hold Time

t

AH 20 --- 20 --- 20 --- ns

12

Non-Muxed Address Valid
Time to E (see note 5)

t

AV1

t

AV2

160

---

---

270

100

---

---
---

50

---

---
---

ns
ns

17

Read Data Setup Time

t

DSR 100 --- 70 --- 60 --- ns

18

Read Data Hold Time

t

DHR 10 --- 10 --- 10 --- ns

19

Write Data Delay Time

t

DDW --- 225 --- 170 --- 160 ns

21

Write Data Hold Time

t

DHW 30 --- 20 --- 20 --- ns

29

Usable Access Time (See
Note 4)

t

ACC 605 --- 310 --- 235 --- ns

Figure 3-4. Read/Write Timing Diagram


Notes:

1. Voltage levels shown are V

L

< 0.4 V, V

H

> 2.4 V, unless otherwise specified.

2. Measurement points shown are 0.8 V and 2.0 V, unless otherwise noted.

3. All electricals shown for the MC6802 apply to the MC6802NS and MC6808, unless otherwise noted.

4. Usable access time is computed by: 12 + 3 + 4 – 17.