Preassembly – Harken 1080 MKIII Jib Reefing & Furling User Manual

Page 21

Advertising
background image

Preassembly

How many foils and connectors • Stringing connectors

April 2000

Unit 3.25 MKIII

11

How Many Connectors?

Use the chart at left to determine the proper number

of 10" (254 mm) connectors for your headstay.
Every unit uses one 13" (330 mm) bottom connector

in addition to the number of 10" (254 mm) connectors

shown at left.
*One additional connector required; order part 960 for

rod and part 1032 for wire.
**Two additional connectors required.

How Many Foils?

Use the chart at left to determine the proper number of

7' (2.13 m) foils for your headstay.
The variable length top foil is cut from one of the 7'

(2.13 m) foils and is used in addition to the number of

foils shown at left.
*One additional foil required; order part 958.
**Two additional foils required.

Stringing Connectors - Rod

Confirm connector inside diameter — .58" (14.7 mm).

See “Connector Bore”, page 3.
After the headstay has been cut to length, but before the

lower terminal is attached, the proper number of con-

nectors must be placed on the headstay in the correct

order.

Every unit uses a top foil trim cap.
Every unit uses a number of 10" (254 mm) connectors

which varies according to the length of the headstay

and is determined by consulting the chart above.
Every unit uses one 13" (330 mm) bottom connector

Slide the trim cap onto the stay so that the open end

faces down.
Slide the proper number of 10" (254 mm) connectors

onto the headstay.
Slide the 13" (330 mm) bottom connector onto the

headstay so that it is closest to the bottom of the head-

stay.
Slide the rod adapter nosepiece onto the stay.
Have the rod coldheaded by a reputable rod service

center. If you ship the rod headstay to a service center

do not coil it tighter than 200 times the rod's diameter.

Norseman/Sta-Lok Instructions
Confirm connector inside diamter — .61" (15.5 mm). See “Connector Bore”, page 3.
Because Norseman and Sta-Lok terminals are applied to the headstay wire after the foil is built, it is not necessary to place the connec-
tors or trim cap on the wire at this time.
Norseman and Sta-Lok units require the same number of foils and connectors as shown above. Identify the parts you need and set them
aside at this time.

Pin-to-Pin Headstay Length (See Pg 7)

Number 10" (254 mm) Connectors

Longueur axe à axe de l'étai (Voir Pg 7)

Nombre de connecteurs de 254 mm utilisés

Bolzen-Bolzen-Mass Anzahl des Vorstages (s.S.7)

Anzahl benötigter Verbinder von 254 mm

Lunghezza perno-a-perno dello strallo (vedi p. 7)

Numero di estrusi da 254 mm usati

53'9" to 54'9" (16.383 m to 16.688 m)

7

54'10" to 61'9" (16.713 m to 18.821 m)

8

61'10" to 68'9" (18.847 m to 20.955 m)

9

68'10" to 75'9" (20.980 m to 23.089 m)

10

75'10" to 82'9" (23.114 m to 25.222 m)

11*

82'10" to 88'9" (25.248 m to 27.051 m)

12**

Pin-to-Pin Headstay Length (See Pg 7)

Number 7' (2.13 m) Foils Used

Longueur axe à axe de l'étai (Voir Pg 7)

Nombre de profils de 2.13 m utilisés

Bolzen-Bolzen-Mass Anzahl des Vorstages (s.S.7)

Anzahl benötigter Profile von 2.13 m

Lunghezza perno-a-perno dello strallo (vedi p. 7)

Numero di estrusi da 2.13 m usati

53'9" to 60'10" (16.383 m to 18.542 m)

7

60'11" to 67'10" (18.567 m to 20.676 m)

8

67'11" to 74'10" (20.701 m to 22.809 m)

9

74'11" to 81'10" (22.835 m to 24.943 m)

10*

81'11" to 88'9" (24.968 m to 27.051 m)

11**