Model and Tooth Preparation

Fabricate a working model with removable segments as usual. The directions of the manufacturers of the

different CAD/CAM systems regarding the plaster to be used must be observed.

Important for die preparation

:

– Check the radius of the incisal/occlusal edge on the prepared die (maxilla and mandible).

– The prepared incisal edge should be at least as thick as the diameter of the bur used in the cavity

during the CAD/CAM process.

– If the incisal edge of the prepared die is thinner than the diameter of the bur, the incisal edge has to

be blocked out accordingly.

– Also observe the information provided by the manufacturer of the CAD/CAM system regarding the die

geometry.

Inlay/onlay

Veneer and anterior crown

Posterior crown

Anterior crown on a ZrO

2

abutment

(Straumann

®

Anatomic IPS e.max

®

Abutment)