Ivoclar Vivadent IPS e.max CAD Labside User Manual

Page 49

Advertising
background image

49

L

a

y

e

ri

n

g

Te

ch

n

iq

u

e

Wash firing (foundation)

The restoration must be free of dirt and grease before the wash firing is done. Any contamination after cleaning must be

prevented.

Please observe the following procedure for the wash firing:

– Clean the framework (free of dirt and grease).

– Conduct the wash firing with Deep Dentin or Dentin materials.

– Use the IPS e.max Ceram Build-Up Liquids allround or soft to mix the materials.

– If a more plastic consistency is desired, IPS e.max Ceram Glaze and Stain Liquid allround or longlife can be used.

– Apply the wash in a thin coat on the entire framework.

– Conduct the wash firing on a honey-combed tray with the corresponding parameters.

Apply the wash using Dentin and/or Deep Dentin materials…

…and fire using the indicated firing parameters

Firing parameters for the Wash firing (foundation firing)

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Layering Technique

[°C/°F]

[min]

[°C/°F/min]

[°C/°F]

[min]

[°C/°F]

[°C/°F]

Wash firing (foundation)

403/757

4:00

50/90

750/1382

1:00

450/842

749/1380

Advertising