Ivoclar Vivadent IPS e.max CAD Labside User Manual
Page 29

29
S
ta
in
in
g
Te
ch
n
iq
u
e
Once the IPS e.max CAD restoration has cooled to room temperature, proceed with the following steps:
– Remove the restoration from the hardened IPS Object Fix Putty or Flow..
– Remove any residue with ultrasound in a water bath and/or with steam.
– Do not blast the framework with Al
2
O
3
or glass polishing beads.
– Place the restoration on the model, check fit and make slight adjustments, if necessary.
– If adjustments by grinding of the restoration are required, make sure that no overheating of the ceramic occurs.
– If the restoration is ground, manually polish the corresponding areas to a high gloss after grinding.
Remove the cool restoration from the hardened IPS Object Fix Putty or Flow.
Remove residue with ultrasound in a water bath…
… or with steam
Do not blast the restoration with Al
2
O
3
IPS e.max CAD LT crown on the model after Combination firing
Onlay and inlay made of IPS e.max CAD HT after Combination firing