Ivoclar Vivadent IPS e.max CAD Labside User Manual

Page 29

Advertising
background image

29

S

ta

in

in

g

Te

ch

n

iq

u

e

Once the IPS e.max CAD restoration has cooled to room temperature, proceed with the following steps:

– Remove the restoration from the hardened IPS Object Fix Putty or Flow..

– Remove any residue with ultrasound in a water bath and/or with steam.

Do not blast the framework with Al

2

O

3

or glass polishing beads.

– Place the restoration on the model, check fit and make slight adjustments, if necessary.

– If adjustments by grinding of the restoration are required, make sure that no overheating of the ceramic occurs.

– If the restoration is ground, manually polish the corresponding areas to a high gloss after grinding.

Remove the cool restoration from the hardened IPS Object Fix Putty or Flow.

Remove residue with ultrasound in a water bath…

… or with steam

Do not blast the restoration with Al

2

O

3

IPS e.max CAD LT crown on the model after Combination firing

Onlay and inlay made of IPS e.max CAD HT after Combination firing

Advertising