Wash firing (foundation) characterization

IPS e.max Ceram Essence is used for individualized characterization. Especially if space is limited, this allows

to give thin areas a true-to-nature design. Use the IPS e.max Ceram Glaze and Stain Liquids allround or

longlife to mix the materials.

Layering materials must not be applied on unfired wash layers (powders and pastes), since this will result in

a delamination of the layering ceramic. The wash (foundation) must be fired before the actual layering

procedure is started.

Apply individualized characterization using Essence.

50

Firing parameters for the Wash firing (foundation firing) characterization

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Layering Technique

[°C/°F]

[min]

[°C/°F/min]

[°C/°F]

[min]

[°C/°F]

[°C/°F]

Wash firing (foundation) characterization

403/757

4:00

50/90

750/1382

1:00

450/842

749/1380