Optional – Ivoclar Vivadent IPS e.max CAD Labside User Manual
Page 50

Optional
Wash firing (foundation) characterization
IPS e.max Ceram Essence is used for individualized characterization. Especially if space is limited, this allows
to give thin areas a true-to-nature design. Use the IPS e.max Ceram Glaze and Stain Liquids allround or
longlife to mix the materials.
Layering materials must not be applied on unfired wash layers (powders and pastes), since this will result in
a delamination of the layering ceramic. The wash (foundation) must be fired before the actual layering
procedure is started.
Apply individualized characterization using Essence.
50
Firing parameters for the Wash firing (foundation firing) characterization
IPS e.max Ceram on IPS e.max CAD
B
S
t
➚
T
H
V
1
V
2
Layering Technique
[°C/°F]
[min]
[°C/°F/min]
[°C/°F]
[min]
[°C/°F]
[°C/°F]
Wash firing (foundation) characterization
403/757
4:00
50/90
750/1382
1:00
450/842
749/1380