Crystallization – Ivoclar Vivadent IPS e.max CAD Labside User Manual

Page 36

Advertising
background image

36

Veneer and anterior crown on dies

Anterior crown on ZrO

2

abutment (Straumann

®

Anatomic IPS e.max

®

Abutment)

Do not place the IPS e.max CAD restoration on metal pins and do not use a honey-combed
firing tray

Slightly overfill the restoration cavity with IPS Object Fix Putty or Flow

Place the restoration on the IPS e.max CAD Crystallization Tray

Place the firing tray in the furnace and start the crystallization with the respective parameters

Crystallization

The following points should be observed for the crystallization:

– Crystallization should be carried out in an Ivoclar Vivadent furnace (e.g. Programat P300, P500 or

P700).

– Use only IPS Object Fix Putty or Flow as an auxiliary firing paste to ideally place the restoration on the

firing tray.

– Slightly overfill the restoration with the auxiliary firing paste so that there is a reservoir.

– Use only the IPS e.max CAD Crystallization Tray, since it stores the heat necessary for slow and above all tension-free

cooling of the restoration.