IPS e.max Ceram on IPS e.max CAD – Layering Technique

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Layering Technique

°C/°F

min.

°C/°F/min

°C/°F

min.

°C/°F

°C/°F

Wash firing (foundation)

403/757

4:00

50/90

750/1382

1:00

450/842 749/1380

Wash firing (foundation) characterization

403/757

4:00

50/90

750/1382

1:00

450/842 749/1380

1. Dentin / Incisal Firing

403/757

4:00

50/90

750/1382

1:00

450/842 749/1380

2. Dentin / Incisal Firing

403/757

4:00

50/90

750/1382

1:00

450/842 749/1380

Stain Firing

403/757

6:00

60/108

725/1337

1:00

450/842 724/1335

Glaze Firing

403/757

6:00

60/108

725/1337

1:00

450/842 724/1335

Add-On with Glaze Firing

403/757

6:00

60/108

725/1337

1:00

450/842 724/1335

Add-On after Glaze Firing

403/757

6:00

50/90

700/1292

1:00

450/842 699/1290

IPS e.max Ceram on IPS e.max CAD-Cut – Back Technique

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Cut-Back Technique

°C/°F

min.

°C/°F/min

°C/°F

min.

°C/°F

°C/°F

Wash firing (foundation)

403/757

4:00

50/90

750/1382

1:00

450/842 749/1380

Incisal firing

403/757

4:00

50/90

750/1382

1:00

450/842 749/1380

Stain firing

403/757

6:00

60/108

725/1337

1:00

450/842 724/1335

Glaze firing

403/757

6:00

60/108

725/1337

1:00

450/842 724/1335

Add-On with Glaze Firing

403/757

6:00

60/108

725/1337

1:00

450/842 724/1335

Add-On after Glaze firing

403/757

6:00

50/90

700/1292

1:00

450/842 699/1290

IPS e.max Ceram on IPS e.max CAD – Staining Technique

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Staining Technique

°C/°F

min.

°C/°F/min

°C/°F

min.

°C/°F

°C/°F

Stain and Characterization firing

403/757

6:00

60/108

770/1418 1:00-2:00 450/842 769/1416

Glaze firing

403/757

6:00

60/108

770/1418 1:00-2:00 450/842 769/1416

Add-On after Glaze Firing

403/757

6:00

50/90

700/1292

1:00

450/842 699/1290

64

e.max

®

CAD

Firing parameters

IP

S

– Use a honey-combed tray and the corresponding pins for firing.

– Ceramic pins must not be used, since they may fuse to the restoration.

– The processing temperatures must be observed. An increase in the firing temperature results in severe vitrification

between the framework and the veneering ceramic, which may lead to cracks later. An decrease in the firing

temperature causes the ceramic to be underfired and very brittle, which may lead to delamination.

– The parameters stipulated in the Instructions for Use are coordinated with Ivoclar Vivadent furnaces (tolerance range

+/- 10 °C).

– If a non-Ivoclar Vivadent furnace is used, temperature corrections may be necessary.

– Remove IPS e.max CAD objects from the furnace after completion of the firing cycle (wait for the acoustic signal of the

furnace).

– Allow the objects to cool to room temperature in a place protected from draft.

– Do not touch the hot objects with metal tongs.

– Do not blast or quench the objects.

Advertising