Ivoclar Vivadent IPS e.max CAD Labside User Manual

Page 52

Advertising
background image

2

nd

Dentin and Incisal firing (Corrective firing)

Compensate for the shrinkage and complete the missing areas.

Stain and Glaze firing

Stain firing is conducted with IPS e.max Ceram Essence and

IPS e.max Ceram Shades, while Glaze firing is carried out

with IPS e.max Ceram Glaze (powder, paste or spray).

Depending on the situation, the Stain and Glaze firings may

be conducted together or separately one after the other. The

firing parameters are identical.

Compensate for the shrinkage with Dentin, Transpa and Incisal materials

Completed, stained and glazed IPS e.max CAD MO restoration

Then the restoration is fired using the firing parameters for the 2

nd

Dentin and Incisal firing

52

Firing parameters for the 2

nd

Dentin and Incisal firing

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Layering Technique

[°C/°F]

[min]

[°C/°F/min]

[°C/°F]

[min]

[°C/°F]

[°C/°F]

2

nd

Dentin and Incisal firing

403/757

4:00

50/90

750/1382

1:00

450/842

749/1380

Firing parameters for the Stain and Glaze firing

IPS e.max Ceram on IPS e.max CAD

B

S

t

T

H

V

1

V

2

Layering Technique

[°C/°F]

[min]

[°C/°F/min]

[°C/°F]

[min]

[°C/°F]

[°C/°F]

Stain firing

403/757

6:00

60/108

725/1337

1:00

450/842

724/1335

Glaze firing

403/757

6:00

60/108

725/1337

1:00

450/842

724/1335