After glazing and staining, the Combination firing (crystallization/glaze) is conducted in a compatible ceramic furnace

(e.g. Programat

®

P700). When placing the objects into the furnace and setting the firing parameters, observe the following

points:

– Place the restoration including the pin into the center of the IPS e.max CAD Crystallization Tray.

– Place veneers, inlays and onlays directly on the IPS e.max CAD Crystallization Pin with a small amount of IPS Object Fix

Flow.

– A maximum of 6 restorations can be positioned on the firing tray and crystallized using the Combination firing with

IPS e.max CAD Crystall./Glaze Paste.

– Conduct the Combination firing (Speed Crystallization/Glaze LT/HT) using the stipulated parameters.

If additional characterizations or adjustments are required after crystallization, a corrective firing using

IPS e.max CAD Crystall./Shades, Stains and Glaze can be conducted. Conduct the corrective firing also on the

IPS e.max CAD Crystallization Tray.

For minor shape adjustments (e.g. proximal or occlusal contact points), IPS e.max CAD Crystall./Add-On is

available . The adjustments may be made with both Crystallization/Glaze and Corrective firing.

The detailed procedure is described on page 30.

Furnace

P300

P500

P700

Stand-by

temperature

B

[°C/°F]

403/757

Closing time

S

[min]

6:00

Heating rate

t

1

[°C/°F/min]

90/162

Firing

temperature

T

1

[°C/°F]

820/1508

Holding time

H

1

[min]

0:10

Heating rate

t

2

[°C/°F/min]

30/54

Firing

temperature

T

2

[°C/°F]

840/1544

Holding time

H

2

[min]

7:00

Vacuum 1

1

1

[°C/°F]

1

2

[°C/°F]

550/820

1022/1508

Vacuum 2

2

1

[°C/°F]

2

2

[°C/°F]

820/840

1508/1540

Long-term

cooling

L

[°C/°F]

700/1292

Cooling rate

t

[°C/°F/min]

0

Furnace

P300

P500

P700

Stand-by

temperature

B

[°C/°F]

403/757

Closing time

S

[min]

6:00

Heating rate

t

1

[°C/°F/min]

90/162

Firing

temperature

T

1

[°C/°F]

820/1508

Holding time

H

1

[min]

0:10

Heating rate

t

2

[°C/°F/min]

30/54

Firing

temperature

T

2

[°C/°F]

840/1544

Holding time

H

2

[min]

3:00

Vacuum 1

1

1

[°C/°F]

1

2

[°C/°F]

550/820

1022/1508

Vacuum 2

2

1

[°C/°F]

2

2

[°C/°F]

820/840

1508/1540

Long-term

cooling

L

[°C/°F]

700/1292

Cooling rate

t

[°C/°F/min]

0

Firing parameters Crystallization/Glaze LT/HT

Please note:

– Crystallization/Glaze HT/LT can only be used for IPS e.max CAD HT and LT.

– IPS e.max Ceram materials (Essences, Shades etc.) must not be used in combination with IPS e.max CAD

Crystall./Glaze, Shades and Stains.

Firing parameters for the Corrective firing

Note

Cooling after firing

– Remove IPS e.max CAD objects from the furnace after completion of the firing cycle (wait for the acoustic

signal of the furnace).

– Allow the objects to cool to room temperature in a place protected from draft.

– Do not touch the hot objects with metal tongs.

– Do not blast or quench the objects.

Advertising