Ivoclar Vivadent IPS e.max CAD Labside User Manual

Page 38

Advertising
background image

38

Preparing for veneering

Once the IPS e.max CAD restoration has cooled to room temperature, proceed with the following steps:

– Remove the restoration from IPS Object Fix Putty or Flow.

– Remove any residue with ultrasound in a water bath and/or with steam.

Do not blast the framework with Al

2

O

3

or glass polishing beads.

– Place the restoration on the model, check fit and make slight adjustments, if necessary.

– Check margins and finish with rubber wheels, if required.

– Make sure that the minimum thicknesses are maintained even after the minor adjustments.

– Before veneering, clean the framework with the steam jet.

Do not blast the restoration with Al

2

O

3

or glass polishing beads.

Remove the crystallization tray from the furnace once the crystallization program has been
completed and allow it to cool to room temperature

Remove the restoration from the hardened auxiliary firing paste

Do not blast the restoration with Al

2

O

3

Remove residue with ultrasound in a water bath…

… or with steam

Reduced IPS e.max CAD framework prepared for veneering

Advertising