Ivoclar Vivadent IPS e.max CAD Labside User Manual

Page 33

Advertising
background image

33

S

ta

in

in

g

Te

ch

n

iq

u

e

Die fabrication with IPS Natural Die Material

The light-curing IPS Natural Die Material simulates the shade of the preparation. Fabricate a die according to the shade

information supplied by the dentist (shade selection), which serves as the optimum basis for a true-to-nature shade

reproduction of the given oral situation. Please observe the following procedure:

– Coat the inner surfaces of the ceramic restoration with IPS Natural Die Material Separator and allow it to react for a

short time.

– Apply the selected IPS Natural Die Material on the inner aspects of the restoration using the IPS Condenser. Make sure

that the entire inner aspect is covered and filled.

– Insert the IPS Die Holder into the material and adapt excess around the die holder. Make sure that there is no gap at the

restoration margins.

– Cure the IPS Natural Die Material die in a customary light polymerization device for 60 seconds.

– If necessary, the die can be further finished and smoothed after polymerization.

Coat the inner surfaces of the ceramic restoration with IPS Natural Die Material Separator
and allow it to react for a short time.

Apply IPS Natural Die Material in the restoration and place the die holder.

Cure in a customary light polymerization device.

Advertising