Chapter 6: Advanced Topic: SNMP/IVR

To set the IP address, use the following CLI command:

con-MasterChassis> snmptrapip1 <ip>. This command configures the IP address of the network
management site in the Tenor AS unit from which the SNMP traps will be generated. Valid entry:
The index number of 1-3 (the index number is used to designate the index # for the network man-
ager to be used) followed by the IP address for the network management site. You can assign a
Tenor AS unit up to three network managers; each manager will have a different index number.

Assign an IP address as follows:

NOTE:

The following instructions assume your PC is running Windows 95 or later.

1. Click on Start> Run. The Run window will appear.

2. Type telnet in the Open box and click on Ok. The Telnet GUI will launch.

3. Click Connect> Remote System.

4. In the Host Name window, enter the IP address of the unit from which you would like to view

alarms.

5. In the port window, choose telnet (port 23 is the default port for a telnet session).

6. From the TermType drop down list, select vt100.

7. Click Connect. A telnet session will be displayed. (To exit a telnet session at any time, type exit

at the prompt.)

8. Enter the same password you set via CLI.

9. At the config - MasterChassis prompt, type set snmptrapip1 <ip>. For example, type set

snmptrapip1 208.226.140.12. This will assign index of 1 to indicate the first network manager
being assigned to that Tenor AS unit and assign the IP address 208.226.140.12 as the network
manager. To assign the second snmptrap ip, type set snmptrapip2 <ip> and the third type set
snmptrapip3 <ip>.

10.Repeat step 9 for each network manager (up to 3).

11. Type submit. The new IP address(es) will be submitted to the applicable Tenor AS units.