6-8

P/N 480-0059-00-10

Chapter 6: Advanced Topic: SNMP/IVR

Launching Command Line Interface (CLI) from HP Openview

Launch Command Line Interface with pop-up menu as follows:

1. From the HP Openview desktop, right-click on the desired Tenor AS unit icon and select Quin-

tum Analog.

2. The CLI will launch with the IP address of the unit associated with that icon (the correct IP

address will appear in the URL).

3. Configure the unit.

OR

Launch CLI by double-clicking the icon as follows:

1. From the HP Openview desktop, double-click on the desired Tenor AS unit icon and select Quin-

tum Analog.

2. The CLI will launch with the IP address of the unit associated with that icon (the correct IP

address will appear in the URL).

3. Configure the unit. See the Tenor Configuration Manager/Tenor Monitor User’s Guide for more

information.

Set up Tenor AS status polling

The following explains how to configure HPOV to determine and display unit status if the Tenor AS
is not configured to send traps. Polling is only intended for Tenor AS units which are not accessible
to configure the network manager IP address using the Tenor AS’s Command Line Interface (CLI).
We do not recommend polling more than 10 Tenor AS units.

1. From the HP Openview desktop, right-click on the desired Tenor AS unit icon and select Object

Properties.

2. From the Attributes window, select Quintum Tenor AS attributes.

3. Click on Edit Attributes.

4. Select Turn on Tenor Status Polling (the toggle allows you to set to True or False). Select True.

5. Click on Verify. After the verification is complete, click Ok.

Polling occurs in 30 second intervals, or whenever a Tenor AS trap is received.

Set up Debug Message Display window

The following explains how to display debug messages that are generated by the quintum.exe. This
window is used to troubleshoot HPOV processing events for the Tenor AS icons.