Auxiliary configuration screen, Auxiliary configuration screen -11 – Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual
Page 127

V T 1 0 0 I n t e r f a c e
4-11
DTE on the Serial interface. If set to “Forced True,” RTS is always perceived
as “On.”
Values: Normal, Forced True
Default: Normal
RTS/CTS Delay
The Request To Send/Clear To Send parameter determines how long the unit
waits before it changes the level of CTS to match RTS when the CTS
parameter is set to “Internal.”
Values: Normal (~30 ms delay), Long (~100 ms delay)
Default: Normal
DTR Alarm Control
Lets you set DTR Alarm Control parameters.
Values: Enable, Disable
Default: Disable
DTR Alarm Status
Lets you view the current DTR Alarm status.
Format
Selects the port’s operating mode.
Values: Sync, Async
Default: Sync
Flow Control
Selects the type of flow control to be used if the port is asynchronous.
Values: None, Xon/Xoff, RTS/CTS
Default: None
Character Size
Selects the number of bits to make up one asynchronous character.
Values: Five, Six, Seven, Eight
Default: Eight
Parity
Selects the setting for the parity bit if the port is asynchronous.
Values: None, Odd, Even
Default: None
Stop Bit
Selects the number of bits to end the character.
Values: 1, 2
Default: 1
Current Pin Status
The Current Pin Status, which shows the state of the RS-232 pins, is also
displayed on the Serial 1 and Serial 2 screens.
Auxiliary Configuration Screen
The Auxiliary Configuration screen (Figure 4.9) lets you configure the
parameters listed below: