Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual

Page 69

Advertising
background image

W e b S e r v e r I n t e r f a c e

3-39

FrameStart Status

If the remote unit is a Verilink unit with FrameStart technology and
FrameStart Auto Discovery is enabled, the FrameStart Status field will show
the status of the remote unit. The status is “Active” if both the local and
remote DLCIs are active and the remote unit answers to the discovery frames
sent by this unit. The status is “SOS” if the remote unit is active but the
FRAD/Router connected to it is inactive. The status is “Inactive” in all other
cases.

Values: Active, Inactive, SOS
Default: Inactive

Remote DLCI

If the remote unit is a Verilink unit with FrameStart technology, and
FrameStart Auto Discovery is enabled, this displays the DLCI number used
on the remote end of this DLCI.

Values: 16

1023

Default: 0

Remote Unit

If the remote unit is a Verilink unit with FrameStart technology, and
FrameStart Auto Discovery is enabled, this parameter gives the first three
digits of the unit ID configured on the remote end of this DLCI.

Values: 000

999

Default: 000

Remote Unit IP

Address

Displays the IP address of the remote Verilink unit with FrameStart
technology if FrameStart Auto Discovery is enabled.

Round Trip Delay Size

(bytes)

Specifies the frame size (in bytes) of packets making the round trip. If the
Round Trip Delay Size is not configured, the Frame Relay Details values will
be used.

Round Trip Delay Rate

(secs)

Specifies the rate (in seconds) at which Round Trip Delay packets are sent. If
the Round Trip Delay Rate is not configured, the Frame Relay Details values
will be used.

DLCI Status Table

The bottom portion of the screen shows a table detailing the actual status of and
alarm threshold information for the selected DLCI as follows:

Status

If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”

Values: Active, Inactive
Default: Inactive

Receiving FECN/

BECN

When a frame is received with a congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without a congestion
bit set.

Values: Yes, No
Default: No