Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual

Page 154

Advertising
background image

4-38

W A N s u i t e 5 3 7 0

Remote Unit

If the remote unit is a Verilink unit with FrameStart technology, and
FrameStart Auto Discovery is enabled, this field displays the first three digits
of the unit ID configured on the remote end of this DLCI.

Values: 000

999

Default: 000

Remote IP Address

Displays the IP address of the remote Verilink unit with FrameStart
technology if FrameStart Auto Discovery is enabled.

Remote IP Address

Displays the IP address of the unit configured on the remote end of this
DLCI.

Round Trip Delay

Specifies the frame size (in bytes) of packets making the round trip.

Round Trip Rate

Specifies the rate (in seconds) at which Round Trip Delay packets are sent.

DLCI Status Table

The bottom portion of the screen shows a table detailing the actual status of this
DLCI and alarm threshold information as follows:

Status

If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”

Values: Active, Inactive
Default: Inactive

Receiving FECN/

BECN

When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.

Values: Yes, No
Default: No

CIR Threshold

Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.

CIR Alarm

Reports if the Tx over CIR threshold has been exceeded.

Bits Over Be Threshold

Sets the Tx over Be alarm threshold. This threshold is the number of bits per
second in excess of CIR + Be during a 15-minute interval. Setting this field to
“0” (zero) disables the alarm.

Bits Over Be Alarm

Reports if the Tx over Be threshold has been exceeded.

Congestion Threshold

Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.

Congestion Alarm

Reports if the Rx Congestion threshold has been exceeded.

Advertising