Diagnostics screen, Diagnostics screen -46 – Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual

Page 76

Advertising
background image

3-46

W A N s u i t e 5 3 7 0

Figure 3.36

SNMP Details Screen

Read Community

Accepts a character string identifying the group authorized to perform read
operations. The default setting is “Public.”

Write Community

Accepts a character string identifying the group authorized to perform write
operations. The default setting is “Private.”

Trap Community

Accepts a character string that is included in SNMP traps generated by the
unit. The default setting is “Public.”

Trap IP Address

Accepts the IP address of a network device where alarm reporting traps are to
be sent.

The unit detects and reports DDS network alarms and provides several
options for reporting them, one of which is SNMP traps. When a network
alarm occurs, the unit sends a trap message to as many as eight destinations
on your network. The unit will report each alarm by transmitting an SNMP
“trap” to each non-zero Trap IP address.

Diagnostics Screen

The Diagnostics screen (Figure 3.37) provides a table for viewing the current
settings for the test and maintenance functions performed on the available
interfaces. This screen shows an upper-level view of all the interfaces so you
can see if any port is under test, and if so, view the results. Diagnostic
parameters may be changed on the Test Details screen (page 3-48). The
parameters on the Diagnostics screen are described in the paragraphs below.