Snmp details screen, Diagnostics screen, Snmp details screen -44 diagnostics screen -44 – Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual

Page 160

Advertising
background image

4-44

W A N s u i t e 5 3 7 0

SNMP Details Screen

The unit detects and reports network alarms and provides several options for
reporting them, one of which is SNMP traps. When a network alarm occurs,
the unit sends a trap message to as many as eight destinations on your
network. The unit will report each alarm by transmitting an SNMP “trap” to
each non-zero Trap IP address.

The SNMP Details screen (Figure 4.39) lets you configure the SNMP
parameters described in the paragraphs below.

Figure 4.39

SNMP Details Screen

Read Community

Accepts a character string identifying the group authorized to perform read
operations. The default setting is “Public.”

Write Community

Accepts a character string identifying the group authorized to perform write
operations. The default setting is “Private.”

Trap Community

Accepts a character string, which is included in SNMP traps generated by the
unit. The default setting is “Public.”

Trap IP Address

Accepts the IP address of a network device where alarm reporting traps are to
be sent.

Diagnostics Screen

The Diagnostics screen (Figure 4.40) provides a table for viewing the current
settings for the test and maintenance functions performed on the available
interfaces. This screen shows an upper-level view of all the interfaces so you
can see if any port is under test, and if so, view the results. You may change
Diagnostic parameters on the Test Details screen (Figure 4.41), which is
accessed by selecting the appropriate interface under the <Description>
column. The properties of the Diagnostics table are described in the
paragraphs below.