Network aps screen, Network aps screen -11 – Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual

Page 145

Advertising
background image

V T 1 0 0 I n t e r f a c e

4-11

Network APS Screen

Configuration of APS parameters and access to collected activity data are
accessible on the Network APS screen shown in Figure 4.7.

Figure 4.7

Network APS Screen

Mode

Four Modes are available to the Network APS. In the TR54017 Mode, units
on each end of the links work together to provide one-way protection (i.e.,
only the impaired direction of service will be restored). In the Auto A/B
Mode, the unit operates as a single-ended A/B switch that can automatically
switch from the active line to the stand-by line if the active line can no longer
carry service. Units configured for the Alternate Carrier Mode work together
so that both carry service on the same line. In the Alt Master Mode, the unit
is configured as the Master side of the Alternate Carrier Mode. In the Alt
Slave Mode, the unit is configured as the Slave side of the Alternate Carrier
Mode.

Values: TR54017, Auto A/B, Alt Master, Alt Slave
Default: TR54017

Manual Inhibit

Three options are available for manually inhibiting a line. If set to “Disabled,”
neither line is manually inhibited from carrying service. If set to “Primary,”
the Primary line is inhibited from carrying service. If set to “Backup,” the
Backup line is manually inhibited from carrying service.

Values: Disabled, Primary, Backup
Default: Disabled

Revert

If disabled, service does not return to the primary line until the backup line
fails. If enabled, service automatically returns to the primary line when the
primary line is able to carry service again.

Values: Disable, Enable
Default: Disable

Advertising