Service table screen, Service table screen -22 – Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual

Page 156

Advertising
background image

4-22

W A N s u i t e 7 1 0 5

Diagnostic Messages

Enables the Supervisory port to send out diagnostic messages upon power-up.

Values: Enable, Disable
Default: Enable

NOTICE:

When in SCADA Mode, these diagnostic messages disrupt the connected
device. Therefore, if using the SCADA Mode, set this value to
“Disable.”

Current Pin Status

Shows the status of the DTE Supervisory port pins.

Service Table Screen

The Service Table screen (Figure 4.16) provides a view of the unit’s defined
services and displays the Interface, Type, and Pair parameters for each
service.

Figure 4.16

Service Table Screen

The Status for a particular service will display as one of the following:

Dead

The service is not functional because required resources are not

available.

Changed

The service parameter was changed and a Save and Restart is

required for the service to function.

Down

The service is not able to pass data because the physical layer is

down.

Physical Up

The service is not able to pass data because it has not

completed any required negotiations.

Up

The service is ready to pass data.

Idle

The service has nothing to do.

The Service Table screen displays the available services listed by Index
number. To view more detailed information about a service, navigate to one
of the Details screen (such as the Service Details screen described on page

Advertising