Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual
Page 162

4-28
W A N s u i t e 7 1 0 5
Idle Pattern
Selects the DS0 idle pattern sent by the unit and lets the unit determine if the
DS0 idle pattern has been sent by the other end.
Values: 0x00
−
0xFF
Default: 0x7F
Figure 4.23
DS0 Monitor 24 Hour History Screen
Figure 4.24
DS0 Monitor 30 Day History Screen
The DS0 Monitor 24 Hour History and 30 Day History screens show the
following statistics for the specified period.
Period
Period for which the DS0 monitor history is displayed.
Timestamp
System-up-time value during which the utilization historical period was
completed.
% Utilization of __
DS0(s)
Percent of DS0s utilized (
−
1, 0
−
100%) over the period. A
−
1 indicates an
invalid value or unavailable data.
High Utilization
Seconds
Number of seconds (0
−
900) greater than or equal to the high utilization
parameter specified for the period in the utilization alarm table.