Cycle parameters – HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 318

Advertising
background image

318

Touch Probe Cycles: Automatic Datum Setting

15.3 D

A

TUM RIDGE CENTER (Cy

c

le 409, DIN/ISO: G409)

Cycle parameters

U

Center in 1st axis Q321 (absolute): Center of the

ridge in the reference axis of the working plane. Input
range –99999.9999 to 99999.9999

U

Center in 2nd axis Q322 (absolute): Center of the

ridge in the minor axis of the working plane. Input
range –99999.9999 to 99999.9999

U

Width of ridge Q311 (incremental): Width of the

ridge, regardless of its position in the working plane.
Input range 0 to 99999.9999

U

Measuring axis (1=1st axis / 2=2nd axis) Q272: Axis

in which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis

U

Measuring height in the touch probe axis

Q261 (absolute): Coordinate of the ball tip
center (= touch point) in the touch probe axis in
which the measurement is to be made. Input
range –99999.9999 to 99999.9999

U

Setup clearance Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range
0 to 99999.9999

U

Clearance height Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
–99999.9999 to 99999.9999

U

Number in table Q305: Enter the number in the

datum/preset table in which the TNC is to save the
coordinates of the ridge center. If you enter Q305=0,
the TNC automatically sets the display so that the
new datum is on the slot center. Input range 0 to
2999

U

New datum Q405 (absolute): Coordinate in the

measuring axis at which the TNC should set the
calculated ridge center. Default setting = 0. Input
range: -99999.9999 to 99999.9999

X

Y

Q322

Q321

Q31

1

SET_UP(TCHPROBE.TP)

+

Q320

X

Z

Q261

Q260

Advertising