Cycle parameters – HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 381

Advertising
background image

HEIDENHAIN TNC 320

381

16.6 MEA

S

. CIR

C

LE OUTSIDE

(Cy

c

le 422, DIN/ISO: G422)

Cycle parameters

U

Center in 1st axis Q273 (absolute): Center of the stud

in the reference axis of the working plane. Input range
–99999.9999 to 99999.9999

U

Center in 2nd axis Q274 (absolute): Center of the

stud in the minor axis of the working plane. Input
range –99999.9999 to 99999.9999

U

Nominal diameter Q262: Enter the diameter of the

stud. Input range 0 to 99999.9999

U

Starting angle Q325 (absolute): Angle between the

reference axis of the working plane and the first touch
point. Input range –360.0000 to 360.0000

U

Stepping angle Q247 (incremental): Angle

between two measuring points. The algebraic
sign of the stepping angle determines the
direction of rotation (negative = clockwise). If you
wish to probe a circular arc instead of a complete
circle, then program the stepping angle to be less
than 90°. Input range: -120.0000 to 120.0000

X

Y

Q325

Q247

Q278

Q262

Q277

Q274

±Q280

Q273

±Q279

SET_UP(TCHPROBE.TP)

+