Cycle parameters – HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 338

Advertising
background image

338

Touch Probe Cycles: Automatic Datum Setting

15.8 D

A

TUM FR

OM OUTSIDE OF CORNER (Cy

c

le 414, DIN/ISO: G414)

Cycle parameters

U

1st meas. point 1st axis Q263 (absolute): Coordinate

of the first touch point in the reference axis of the
working plane. Input range –99999.9999 to
99999.9999

U

1st meas. point 2nd axis Q264 (absolute):

Coordinate of the first touch point in the minor axis of
the working plane. Input range –99999.9999 to
99999.9999

U

Spacing in 1st axis Q326 (incremental): Distance

between the first and second measuring points in the
reference axis of the working plane. Input range 0 to
99999.9999

U

3rd meas. point 1st axis Q296 (absolute): Coordinate

of the third touch point in the reference axis of the
working plane. Input range –99999.9999 to
99999.9999

U

3rd meas. point 2nd axis Q297 (absolute):

Coordinate of the third touch point in the minor axis of
the working plane. Input range –99999.9999 to
99999.9999

U

Spacing in 2nd axis Q327 (incremental): Distance

between third and fourth measuring points in the
minor axis of the working plane. Input range 0 to
99999.9999

U

Measuring height in the touch probe axis

Q261 (absolute): Coordinate of the ball tip
center (= touch point) in the touch probe axis in
which the measurement is to be made. Input
range –99999.9999 to 99999.9999

U

Setup clearance Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range
0 to 99999.9999

U

Clearance height Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
–99999.9999 to 99999.9999

X

Y

Q297

Q263

Q326

Q264

Q296

Q327

SET_UP(TCHPROBE.TP)

+

Q320

X

Y

Q261

Q260

Advertising