Cycle parameters – HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 356

Advertising
background image

356

Touch Probe Cycles: Automatic Datum Setting

15.13 D

A

TUM IN ONE AXIS (Cy

c

le 41

9, DIN/ISO: G41

9

)

Cycle parameters

U

1st meas. point 1st axis Q263 (absolute): Coordinate

of the first touch point in the reference axis of the
working plane. Input range –99999.9999 to
99999.9999

U

1st meas. point 2nd axis Q264 (absolute):

Coordinate of the first touch point in the minor axis of
the working plane. Input range –99999.9999 to
99999.9999

U

Measuring height in the touch probe axis

Q261 (absolute): Coordinate of the ball tip
center (= touch point) in the touch probe axis in
which the measurement is to be made. Input
range –99999.9999 to 99999.9999

U

Setup clearance Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range
0 to 99999.9999

U

Clearance height Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
–99999.9999 to 99999.9999

U

Measuring axis (1...3: 1=reference axis) Q272: Axis

in which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis
3: Touch probe axis = measuring axis

X

Y

Q264

Q263

+

–

–

+

Q267

Q272=2

Q272=1

1

SET_UP(TCHPROBE.TP)

+Q320

X

Z

Q260

Q261

+

–

Q272=1

Q272=3

Q267

1

Axis assignment

Active touch probe
axis: Q272= 3

Corresponding
reference axis:
Q272 = 1

Corresponding
minor axis: Q272 = 2

Z

X

Y

Y

Z

X

X

Y

Z

Advertising