HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 331

Advertising
background image

HEIDENHAIN TNC 320

331

15.6 D

A

TUM FR

OM INSIDE OF CIR

C

LE (Cy

c

le 412, DIN/ISO: G412)

U

Probe in TS axis Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

U

Probe TS axis: Coord. 1st axis Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the reference point
is to be set in the touch probe axis. Only effective if
Q381 = 1. Input range –99999.9999 to 99999.9999

U

Probe TS axis: Coord. 2nd axis Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the reference point is to
be set in the touch probe axis. Only effective if Q381
= 1. Input range –99999.9999 to 99999.9999

U

Probe TS axis: Coord. 3rd axis Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the reference point is to be set in the
touch probe axis. Only effective if Q381 = 1. Input
range –99999.9999 to 99999.9999

U

New datum in TS axis Q333 (absolute):

Coordinate in the touch probe axis at which the
TNC should set the datum. Default setting = 0.
Input range: –99999.9999 to 99999.9999

U

No. of measuring points (4/3) Q423: Specify

whether the TNC should measure the hole with 4 or
3 probing points:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points

U

Type of traverse? Line=0/Arc=1 Q365: Definition of

the path function with which the tool is to move
between the measuring points if “traverse to
clearance height” (Q301=1) is active.
0: Move between operations on a straight line
1: Move between operations on the pitch circle

Example: NC blocks

5 TCH PROBE 412 DATUM INSIDE CIRCLE

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SETUP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q423=4

;NO. OF MEAS. POINTS

Q365=1

;TYPE OF TRAVERSE

Advertising