HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual

Page 354

Advertising
background image

354

Touch Probe Cycles: Automatic Datum Setting

15.12 D

A

TUM A

T

CENTER OF 4 HOLES (Cy

c

le 41

8, DIN/ISO: G41

8

)

U

Probe in TS axis Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

U

Probe TS axis: Coord. 1st axis Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the reference point
is to be set in the touch probe axis. Only effective if
Q381 = 1.

U

Probe TS axis: Coord. 2nd axis Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the reference point is to
be set in the touch probe axis. Only effective if Q381
= 1. Input range –99999.9999 to 99999.9999

U

Probe TS axis: Coord. 3rd axis Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the reference point is to be set in the
touch probe axis. Only effective if Q381 = 1. Input
range –99999.9999 to 99999.9999

U

New datum in TS axis Q333 (absolute):

Coordinate in the touch probe axis at which the
TNC should set the datum. Default setting = 0.
Input range: –99999.9999 to 99999.9999

Example: NC blocks

5 TCH PROBE 418 DATUM FROM 4 HOLES

Q268=+20

;1ST CENTER IN 1ST AXIS

Q269=+25

;1ST CENTER IN 2ND AXIS

Q270=+150 ;2ND CENTER IN 1ST AXIS

Q271=+25

;2ND CENTER IN 2ND AXIS

Q316=+150 ;3RD CENTER IN 1ST AXIS

Q317=+85

;3RD CENTER IN 2ND AXIS

Q318=+22

;4TH CENTER IN 1ST AXIS

Q319=+80

;4TH CENTER IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q260=+10

;CLEARANCE HEIGHT

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+0

;DATUM

Advertising