7.2 DEAD ZONE B Instruction (DZB)

7-4

7.2 DEAD ZONE B Instruction (DZB)

[Outline]

The DZB instruction executes a dead zone operation on integer, double-length integer or real number
data.
The following operation is performed, where Input is the input value, Zone is the designated dead zone
value, and Output is the output value:

Output = Input – the absolute value of Zone (the absolute value of Input is greater than or equal

to the absolute value of Zone; Input is greater than or equal to 0)

Output = Input + the absolute value of Zone (the absolute value of Input is greater than or equal

to the absolute value of Zone; Input is less than or equal to 0)

Output = 0 (the absolute value of Input is less than the absolute value of Zone)

+D

-D

X

Y

[Format]

Symbol : DZB
Full Name : Dead Zone B
Category : DDC

Icon :

[Parameter]

Parameter Name

Setting

Input

· Any integer type, double-length integer type and real number type register
· Any integer type, double-length integer type and real number type register

with subscript

· Subscript register
· Constant

Zone

· Any integer type, double-length integer type and real number type register
· Any integer type, double-length integer type and real number type register

with subscript

· Subscript register
· Constant

Output

· Any integer type, double-length integer type and real number type register

(except for # and C registers)

· Any integer type, double-length integer type and real number type register

with subscript (except for # and C registers)

· Subscript register