9.6 Inverter Trace Read Function (ITRC-RD)

9-14

Table 9.5 Configuration of the Inverter Trace Read Execution Status (STATUS)

Name Bit

Name

Remarks

System reserved

Bit 0 to Bit 8

Transmission parameter error

Bit9

The function will not be executed.

System reserved

Bit10

Error in the designated
number of records

Bit11

The function will not be executed.

Data storage error

Bit12

The function will not be executed.

Transmission error

Bit13

The function will not be executed.

System reserved

Bit14

Address input error

Bit15

The function will not be executed.

9.6.1 Readout of Inverter Trace Data

The readout will always be started from the most recent record.

User Register

Readout

Inverter Trace Memory

Number of
read records

Old

New

Head address of the register
into which data is read

Most recent record

9.6.2 Readout Data Configuration

■ Data Configuration

Max. 1920 words

Dat - Adr→1~16 words

1~16 words

1~16 words

Trace data

Old

New

Record 2

Record n

Record 1




ITEM1

ITEM16


■ Record Length

A record is composed of the data of the selected items.
Word length of 1 record = 1 to 16 words

■ Number of Records

Maximum number of records = 120