9.5 Failure Trace Read Function (FTRC-RD)

9-9

9.5 Failure Trace Read Function (FTRC-RD)

[Outline]

Reads the failure trace data and stores them in the user register. The data in the trace buffer can be
read out upon designating the number of records needed. Either the failure occurrence data or the
restoration data are designated for readout. Enables the reset (initialization) of the failure trace buffer.

[Format]

Symbol : FTRC-RD
Full Name : Failure-Trace Read
Category : SYSTEM
Icon :

[Parameter]

I/O

Definition

Parameter Name

I/O

Designation

Setting

Execute

B-VAL

Failure trace readout command

Reset

B-VAL

Failure trace buffer reset command

Type

I-REG

Type of data read
1 : Occurrence data
2 : Restoration data

Rec-Size

I-REG

Number of read records
Occurrence data : 1 to 64 Restoration data : 450

Input

Dat-Adr

Address input

Head register address for reading (address of MW or DW)

Complete

B-VAL

Completion of failure trace read

Error

B-VAL

Occurrence of error

Status

I-REG

Failure trace read execution status

Rec-Size

I-REG

Number of read records

Output

Rec-Len

I-REG

Length of read record

Table 9.3 Failure Trace Read Execution Status (STATUS)

Name Bit

No.

Remarks

System Reserved

Bit 0~Bit 7

No trace definition

Bit8

The function will not be executed.

Designated type No. error

Bit9

The function will not be executed.

System Reserved

Bit10

Error in the designated
number of records

Bit11

The function will not be executed.

Data storage error

Bit12

The function will not be executed.

System Reserved

Bit13

System Reserved

Bit14

Address input error

Bit15

The function will not be executed.