7.4 PI CONTROL Instruction (PI)

7-10

Here, the PI operation is expressed as follows:

Y 1
X

= Kp + Ki×

Ti×S

X : deviation input value

Y : output value

The following operation is performed within the PI instruction:

Ti

Y=Kp×X + {( Ki×X + IREM ) /

Ts

+ Yi'}

Yi' : previous I output value
Ts : scan time set value

Input

X

Kp

Ki

Ts/Ti

Z

-1

I LIMIT

Output

Y

LIMIT

DB

[Format]

Symbol : PI
Full Name : PI Control
Category : DDC

Icon :

[Parameter]

Parameter Name

Setting

Input

· Any integer type and real number type register
· Any integer type and real number type register with subscript
· Subscript register
· Constant

Parameter

· Register address (except for # and C registers)
· Register address with subscript (except for # and C registers)

Output

· Any integer type and real number type register (except for # and C

registers)

· Any integer type and real number type register with subscript (except for #

and C registers)

· Subscript register

Advertising