9.9 Inverter Constant Write Function (ICNS-WR)

9-32

Table 9.14 Configuration of Inverter Constant Write Execution Status (STATUS)

Name Bit

No.

Remarks

System Reserved

Bit 0 to Bit 7

Execution sequence error

Bit8

The function will not be executed.

Transmission parameter error

Bit9

The function will not be executed.

Designated type error

Bit10

The function will not be executed.

Designated No. error

Bit11

The function will not be executed.

Error in number (amount) of the
designated data

Bit12

The function will not be executed.

Transmission error

Bit13

The function will not be executed.

Inverter response error

Bit14

The function will not be executed.

Address input error

Bit15

The function will not be executed.

Note : In the case of an inverter response error, the error codes from the inverter are indicated in bit

0 to bit 7.

01H(1) : function code error
02H(2) : reference No. error

03H(3) : write-in count error
21H(33) : write-in data upper/lower limit error

22H(34) : write-in error (during running, during UV)

9.9.1 Configuration of the Write-in Data

bn-01

ASR integration time

PG dividing ratio




bn-05

bn-14

Cns-No

Cns-Size

Constant data 10




Constant data 2

Constant data 1

User register

ASR proportional gain




AO optional output gain




Acceleration time 1

Inverter Constants

bn-25

bn-06

Cns-Typ

Dat-Adr