background image

Model PD650 Large Display Process Meter

Instruction Manual

10

Specifications

Except where noted all specifications apply to operation at +25°C.

Basic Process Meter

INPUTS

Field selectable:
4-20 mA, 0-20 mA, 0-5 V, 1-5 V, 0-10 V

DISPLAY

Six digit, 2.3" (57.3 mm) high efficiency red LED.
Rate: -19999(0) to 29,999(0) with selectable extra zero
Total: 0 to 999,999; automatic lead zero blanking

DECIMAL POINT

Process/rate display: Decimal point may be placed in any of the
following positions. 2.9999, 29.999, 299.99, 2999.9, or 299990.
Total decimal point: 9.99999, 99.9999, 999.999, 9999.99, or
99999.9. Rate and total decimal points are independent of each
other.

CALIBRATION
RANGE

4 mA (1 V) input may be set anywhere in range of the meter.
20 mA (5 V) may be set anywhere in range of the meter above
or below 4 mA input. An Error message will appear if input 1
signal and input 2 signal are too close together.

Input Range

Minimum Difference Between
Input 1 & Input 2

0-5 V

0.16 V

0-10 V

0.32 V

4-20 mA

1.60 mA

INPUT IMPEDANCE

Voltage ranges: greater than 300 K

Ω

Current ranges: 100

Ω

LOOP POWER

Two isolated power supplies, 24 VDC ± 5% @ 20 mA each,
regulated. Maximum loop resistance is 1200

Ω.

ACCURACY

Linear input: ±0.05% of calibrated span ±1 count

Root extraction: ±0.1% FS ± 2 counts

ROOT EXTRACTION

Square root extraction: Automatic

Programmable exponent: Greater than 1.0000 and smaller than
3.0000

11-POINT

Input Range

Minimum Span Between Inputs

LINEARIZATION

4-20 mA

(1.6 mA ÷ (Number of points -1))

0-5 V

(0.16 V ÷ (Number of points -1))

0-10 V

(0.32 V ÷ (Number of points -1))

e.g. Minimum span for an 11-point, 4-20 mA calibration is
0.16 mA between inputs.

TIME BASE

Second, minute, hour, or day

ALARM POINTS

Four, any combination of high or low alarms

ALARM POINT
DEADBAND

0-100% of full scale, user selectable

ALARM STATUS
INDICATION

Front panel LED

Advertising