Precision Digital PD650 User Manual

Page 70

Advertising
background image

Model PD650 Large Display Process Meter

Instruction Manual

70

Applications Using Total Conversion Factor and Time Base

The following tables illustrate the effect various total conversion factors and time
bases have on the operation of the meter:

Application #1

Rate

Time

base

Total

conv

factor

Total

after one

second

Total

after one

minute

Total

after one

hour

Total

after one

day

60

GPM

Min 1

1

gallon

60

gallons

360

gallons

8640

gallons


In the above application, a totalizer conversion factor of 1 with a rate of 60 GPM
results in a total of 60 gallons after 1 minute.

Application #2

Rate Time

base

Total

conv

factor

Total

after one

second

Total

after one

minute

Total

after one

hour

Total

after one

day

60

GPM

Min 0.2 0.2

can

12

cans

720

cans

17280

cans


In the above application, 5 gallon paint cans are being filled and the user wants
to keep track of the number of cans that have been filled, not the total gallons of
paint that has been dispensed.

Application #3

Rate Time

base

Total

conv

factor

Total

after one

second

Total

after one

minute

Total

after one

hour

Total

after one

day

10

MGD

Day 1 0.0001

0.0069 0.4166

10.0000

Million gls


In the above application, a wastewater treatment plant has an effluent of 10
million gallons per day. A totalizer conversion factor of 1 and a time base of day,
results in a total display of 10.0000 million gallons after one day.

Advertising