2.4.6 Logs Settings

There are a variety of events that can be captured and logged for review. These
logs can be sent to a system logging (syslog) server or emailed as configured.

Parameter

Description

SysLog Server

Enter the IP address or Internet Name of the SysLog server.


The following events (in order of severity) can be logged: Emergency, Alert,
Critical, Error, Warning, Notification, Information, Debugging.

When a particular severity level is selected, all events with severity equal to and
greater than the chosen severity are logged on the configured SysLog server.
For example if this is configured as CRITICAL, then logs with severities
CRITICAL, ALERT, and EMERGENCY are logged.
The severity levels available for logging are:

Parameter

Description

EMERGENCY

System is unusable

ALERT

Action must be taken immediately

CRITICAL

Critical conditions

ERROR

Error conditions

WARNING

Warning conditions

NOTIFICATION

Normal but significant condition

INFORMATION

Informational

DEBUGGING

Debug-level messages


Click