2.3

Diagnostics

The Main Diagnostics tab shows basic information about the radio.

Parameter

Description

Unit Up Time

The length of time the radio has operated since the last system power-
up or last system reset.

Firmware

The version of firmware currently installed. All radios on the network
must have the same firmware versions installed. For more information
on firmware versions, refer to Upload Code (page 96).

2.3.1 Radio Status

Parameter

Description

MAC ID

The MAC address of the selected radio. The MAC ID is also printed on
the side of the radio.

Link Status



Master: The radio is configured as a Master.



Connected: The radio is currently connected to a Parent



Associated: The radio is associated with a Parent, but is not
currently connected



Connecting: The radio is attempting to connect to a Parent



Disconnected: The radio is unable to connect to a Parent

Parent

The MAC address of the parent radio to which the selected radio is
linked.

Link Time

The length of time the radio has been continuously connected to a
parent radio.

RSSI

Strength of the signal from the Parent radio, in dBm.

SNR

The signal-to-noise ratio is displayed here in dB. Refer to
Understanding Signal to Noise Ratio (page 133) for more information
on how to interpret this value.

Poll Interval

Enter the interval in seconds to refresh the status information on this
page.

Start

Click to start refreshing the page.

Stop

Click to stop refreshing the page.

Advertising