124 Understanding Error States

Chapter 4

Slave card failed

Library slave controller card failed

power-up test.

Note:

Slave controller cards are

required in all but the lowest level of

the library.

Verify that a slave card is present

in all but the lowest level of the

library.

Verify that the cards are properly

seated.

Power cycle the library.

Contact your service

representative.

Fibre Channel

controller failed

Fibre Channel controller failed

power-up test. (Usually due to

problems on the SCSI bus, such as

an LVDS drive or terminator on an

HVDS bus, etc.)

Verify that proper SCSI

terminators and/or tape drives

are attached to the Fibre Channel

controller.

Verify that there are no bent pins

on the controller.

Power cycle the library.

Contact your service

representative.

Front Panel

Front panel not

present

Library could not detect the front

panel display.

Power cycle the library.

Contact your service

representative.

Front panel failed

Front panel display failed power-up

test.

Power cycle the library

Contact your service

representative.

Miscellaneous

Date and time not

set

The date and time is not set on the

front panel

Set the date and time. (See

Setting

the Date and Time

on page 108.)

Door open

One or more tape doors are open.

The library robotics will not move

until the door is closed.

Ensure that doors are closed.

Table 18

Partial Availability Conditions

Library Status

Cause

Solution