Choosing a location, Choosing a location 14 – HP 20-Feb User Manual

Page 16

Advertising
background image

14 Choosing a Location

Chapter 1

Choosing a Location

Choose a location that meets the criteria listed in

Table 2

. For additional

specifications, refer to

Technical Specifications

on page 181.

Table 2

Location Criteria

Room temperature 10-35º C (50-95º F)

Power source

AC power voltage: 100-127 V or 200-240 V

Line frequency: 50-60 Hz

A dedicated circuit is required.

Caution:

The AC power cord is the library’s main AC disconnect device and

must be easily accessible at all times.

LAN connection

Locate the library near a LAN connection for connecting the RMC (remote

management card).

Library power

consumption

2/20 series
4/40 series
6/60 series
8/80 series
10/100 series

Max: 200W
Max: 375W
Max: 560W
Max: 725W
Max: 1,200W

Air quality

Minimal sources of particulate contamination. Avoid areas near frequently used

doors and walkways, stacks of supplies that collect dust, and smoke-filled rooms.

Caution:

Excessive dust and debris can damage tapes and tape drives.

Humidity

20-80% RH

Advertising