Running library diagnostic tests, Running library diagnostic tests 156, Running library diagnostic – HP 20-Feb User Manual

Page 158: Tests

Advertising
background image

156 Diagnostic Support Tools

Chapter 4

Running Library Diagnostic Tests

Use the following procedure to run internal tests of library functions.

Table 28

on page 156 describes these tests.
1. From

Administration

, select

[More]

to display additional administrative

options. Select

[Run Test]

.

2. From

Run Test

, use the

[-]

or

[+]

key to view available tests.

3. Select

[OK]

to select the test.

4. Select the number of times this test will run.
5. Select

[Run]

to start the test cycle. The test results will display at the

conclusion of the test cycle.

Note

Select

[Stop]

to abort a test. The current test cycle completes

before the test stops. Stopping the test may take a few minutes.

Main Menu -> Administration -> Run Test

Table 28

Front Panel Diagnostic Tests

Test

Description

Check Inventory

Physically scans the entire library to determine

which slots and drives contain tapes and reads all

bar code labels.

Recalibrate Library

Performs the power-up self-tests. Each test runs one

time per test loop. This test recalibrates the

mechanics and clears hard errors, but not the hard

error log.

Test Lateral Motion

Moves the transport assembly to a random slot. No

tape is required.

Test Magazine

Moves

Moves a tape from a random slot to an empty,

random slot, and then returns it to the original

location.

Advertising