HP 20-Feb User Manual

Page 214

Advertising
background image

212 Library Error Codes

Appendix

21

15H

A chassis fan is

disconnected or

faulty.

Check that the chassis fan cable connection is

secure.

22

16H

Chassis interconnect

cables are

disconnected or

faulty.

Check that the chassis interconnect cables are

secure.

23

17H

Front panel cable is

disconnected or

faulty.

Check that the front panel cable connections are

secure.

24

18H

Transport bar code

reader failed self test.

Power cycle the library.

25

19H

Library levels

measured does not

match the number of

levels detected.

Check for obstructions in the vertical path.

Check that the chassis interconnect cable

connection is secure.

26

1AH

Upper level fan cable

failed.

See

Troubleshooting Common Problems

on

page 140 for troubleshooting procedures.

27

1BH

Transport controller

unable to

communicate with

transport.

Replace the transport assembly.

28

1CH

Transport controller

needs new firmware.

Update the library’s firmware (see

Upgrading

Firmware

on page 176).

29

1DH

Failed transport

firmware download.

Update the transport’s firmware (see

Upgrading

Firmware

on page 176).

50

32H

Test not run, an

invalid test number

was specified.

If incorrect test number was designated when

initiating a test over the SCSI interface, select

desired number and then re-initiate the test.

Table 46

Error Codes and Recovery Procedures

Decimal

Error

Hex

Error

Description

Recovery Method

Advertising