HP 20-Feb User Manual

Page 213

Advertising
background image

Appendix

Library Error Codes 211

Appendix C

11

0BH

Failed plunge motor

test.

Note the error code qualifier to help determine

appropriate testing.

12

0CH

Transport failed to

find the translate

home position.

Make sure that all tape cartridges are fully

seated in their slots.

13

0DH

Transport failed to

find the vertical home

position.

Check for a possible obstruction in the

transport pathway and remove it.

Verify that the vertical path is physically clear.

Make sure that all tape cartridges are fully

seated in their slots. (When manually loaded,

cartridges may not have been fully inserted into

slots.)

14

0EH

Transport failed to

find the plunge home

position.

The plunge motor can be moved. Therefore, the

motor and umbilical cable are probably not

indicated.

Replace the transport assembly.

15

0FH

Has wrong library

family firmware or the

controller is on the

wrong level.

Download new firmware (see

Upgrading Firmware

on page 176).

18

12H

Failed because

magazine door) is

open.

Close magazine doors.

19

13H

Vertical motor cable is

missing or faulty.

Check that the vertical cable connections are

secure.

20

14H

Transport umbilical

cable is missing or

faulty.

Check the transport cable connections or the cable

that goes from the transport to the library.

Table 46

Error Codes and Recovery Procedures

Decimal

Error

Hex

Error

Description

Recovery Method

Advertising