Removing and replacing the power supply, Removing the power supply, Removing and replacing the power supply 167 – HP 20-Feb User Manual

Page 169: Removing the power supply 167

Advertising
background image

Chapter 5

Removing and Replacing the Power Supply 167

Ch

apter 5

Removing and Replacing the Power Supply

A failing power supply on a 2/20 series library disables the library. A failing

power supply on upper library levels results in a partial availability state.

Note

Power cycling the library at this point will result in a hard error. If

you want to continue using the library in its partially available

state, do not power cycle.

When the library is in a partial availability state, it is still functional, but is not

in optimum configuration. When this occurs, the front panel will display

Partly

Available

, and the illuminated LED beneath the front panel display will be solid

amber until the condition is resolved (see

Table 26

on page 139).

Removing the Power Supply

1. Power off the library.
2. Disconnect the power cord from the back of the power supply.
3. Loosen the thumbscrews at the top and bottom of the power supply. If the

thumbscrews are too tight to loosen by hand, loosen them with a

screwdriver.

4. Remove the stop bracket (if applicable). See

Figure 56

on page 171.

5. Remove the power supply with one hand by pulling outward (see

Figure

56

on page 171). Support the bottom of the power supply to avoid

dropping the module.